This website uses cookies. Find out why they are used read our privacy policy. x
By browsing this website you agree to use cookie files, in accordance with the current browser settings.

Filters

Photo of product family: Filters

Why duct filters are so important?

Air filters prevent contaminants from flowing with the air supplied into rooms and ventilation ductwork. This helps operate a ventilation system which
provides air treatment to high hygiene standards while improving the service life of ventilation equipment.

The filter elements are easy to replace both in round and square
duct filters, providing superior convenience of operation and servicing.

In our offer we have filter boxes for rond ductwork - in diameters range
100 to 400 mm and for square/ rectangular ductwork in dimensions ranging
from 200x200 to 2000x2000 mm.

Filters - Products range
Miniature picture Product code Name of product Files to download
Photo of product Electrostatic precipitator e-MOCarz e-MOCarz

Electrostatic precipitator e-MOCarz

 

Electrostatic precipitator e-MOCarz was design for residential
buildings. Compact size and exceptionally low pressure drop
makes it suitable for residential heat recovery systems, with
little impact on system performance. The filtration efficiency
of ePM1 and ePM2.5 particles, the main component of
smog, is as high as 95%.
Polluted air initially passes through a steel mesh pre-filter
(which retains larger fractions), then is positively ionized in
an electric field due to the “crown discharge” effect. In the
last stage, the previously charged particles, are pulled by
electrostatic force toward horizontally mounted aluminium
plates (electrodes) and build up on their surface.
Electrostatic filters (precipitators) have low power consumption
(only few Watts), long service life and most of all there’s no
need to exchanged dirty (clogged) filters. It is enough to
clean in with water and detergent once or twice a year. There
is a led status indicator on the casing.

Available accessories:
e-MOCarz-W - renewable electrostatic filter, included in the set
e-MOCarz-ION - Ionizing module, additionally sterilizing and revitalizing air
e-MOCarz-CA - Activated carbon module, additional filtration of odors
e-MOCarz-... - round connector Ø160, Ø200, Ø250)

 

Electrostatic precipitator e-MOCarz
Photo of product Smog filter box MOCarz / MOCarz-CA

Smog filter box


The smog filter is designed for effective filtration of the
so-called particulate matter. The PM2.5 and PM10 particles are
the main component of smog, which have an optical diameter
of 2.5 and 10 μm (micrometers). The filtration efficiency
(removal) of PM2.5 particles reaches up to 73%, and PM10
particles up to 81% (according to tests carried out with a dust
particle measuring device).

The smog duct filter consists of a sealed filter box and two filters:
prefilter and smog filter. It is recommended to install a smog filter on
the supply ducts in domestic ventilation and heat recovery systems.

Filter replacement (filter set for 1 filter box):
FSBQ-I3 - prefilter
MOCarz-W - proper filter

Smog filter box
Photo of product Duct filter for air filtration in round ventilation ducts UFI

Duct filter for air filtration in round ventilation ducts


Duct mounted filters are designed for filtering air flowing through circular, spiral ducts. The duct filter box is provided with a class EU4 filter element
secured with a galvanized steel wire mesh on both sides. The casing of filter box is made of a round, galvanized sheet duct piece
with spigots fitted with seals for airtight connection.

How to replace a filter element?

Duct mounted filter boxes are equipped with a toggle clamp that allows easy replacement
of the filter element. Filter replacements for UFI filter box are available - UFI-W. The UFI duct filters are designed for installation
between the two sections of spiral duct in the standard diameter range (100-400 mm).

Duct filter for air filtration in round ventilation ducts
Photo of product Filters F-STR

Filters


F-STR duct filters are designed for installation at the point of
connection between round ducts and ventilation fittings.

The conical filter element form provides better filtration
efficiency and reduces the pressure loss across the filter.
The standard filtration class is EU4 or EU5.
The maximum operating temperature is 120˚C.

Filters
Photo of product Replacement filter for the UFI filter housing UFI-W

Replacement filter for the UFI filter housing


UFI-W is a class EU4 filter element designed for filtering air
flowing through round ducts. It is protected with a 1 mm
wire mesh of galvanized steel on both sides. The mesh size
is 1x1 mm on one side and 10x10 mm on the other.

The filter element casing is a 20 mm tall round duct piece.
The UFI-W filter elements are replaceable components of UFI duct filters.

Replacement filter for the UFI filter housing
Photo of product Duct mounted filter box FSBQL

Duct mounted filter box


The FSBQL duct filters are designed for filtering air flowing
through round ducts in the standard diameter range of 100-
500 mm.

The FSBQL duct filter casing is a galvanized steel sheet box
with a top closure fastened with clasps. The box features
connectors with EPDM gaskets. The dedicated design of the
FSBQL duct filters allows easy replacement of the filter element.
The FSBQL duct filters can be provided with class EU3 and
EU5 filter elements.

Duct mounted filter box
Photo of product Filtr element for FSBQL filter box FSBQ-I

Filtr element for FSBQL filter box


The FSBQ-I filter elements are designed for use in the FSBQL
duct filters. The design of this filter element is very simple: the
filter element mat is sewn over a steel wire frame. The FSBQ-I
filter elements are available in filtration classes EU3 and EU5.

The filter elements can be fabricated on request with an
activated carbon mat rated at EU4.
All filter elements are wrapped in protective plastic film which
must be removed before installation.

Filtr element for FSBQL filter box
Photo of product Spare filter for FSBQL filter boxes FSBQ-W

Spare filter for FSBQL filter boxes


The FSBQ-W filter elements are designed for use in the FSBQL
duct filters. The filter elements are made of pleated filter element
mats and reinforced with a steel wire mesh.

The FSBQ-W filter elements are available in filtration classes
EU3 and EU5.All filter elements are wrapped in protective plastic film
which must be removed before installation.

Spare filter for FSBQL filter boxes
Photo of product Filter cassettes for rectangular ducts FSCQ

Filter cassettes for rectangular ducts


The FSCQ cartridge filters are designed for filtering air flowing
through square ducts. The casing of each FSCQ cartridge filter
is the square duct in which it is installed. The cartridge filter
is inserted into the square duct from above, and then locked
and sealed in place with clasps.

This design of the FSCQ cartridge filter allows easy replacement
of the filter element. The filter element is made of a pleated filter
element mat protected by a galvanized steel wire mesh. The
FSCQ cartridge filters can be provided with class EU3/G3, EU4/G4,
EU5/G5, and EU6/G6 filter elements. Optional filter elements
include versions for separation of grease fumes and oil mist
vapour. The cartridge filters are available in aluminium,
galvanized steel or stainless steel for long service life and
regenerability.

Filter cassettes for rectangular ducts
Photo of product Filter cassettes for rectangular ducts FSQ

Filter cassettes for rectangular ducts


The FSCQ pocket filters are designed for filtering air flowing
through square ducts. The casing of each FSQ pocket filter
is the square duct in which it is installed. The pocket filter is
inserted into the square duct, and then locked and sealed in
place with clasps.

This design of the FSQ cartridge filter allows easy replacement
of the filter element. The FSQ pocket filters can be provided
with class EU3 or EU5 filter elements

Filter cassettes for rectangular ducts