VAV or CAV?
CAV (Constant Air Volume) is a control system that keeps the airflow constant, regardless of the current airflow delivered by the air handling unit (airflow stabilisation). A constant air volume ventilation system is usually used to supply air to a single room or zone only – this approach is suitable in some cases, but it does not offer high energy efficiency.
A variable air volume control system (VAV – Variable Air Volume), on the other hand, serves multiple rooms and zones from one or more central plants. It can be controlled according to the actual room load (temperature, air quality or humidity), a time schedule or, for example, a minimum airflow, a required pressure difference or a specified number of air changes in the room. The ventilation output is variable – this approach delivers a high level of energy efficiency. VAV is also used in demanding environments such as cleanrooms and fume cupboards.
That makes sense, but my system needs communication...
Siemens VAV controllers ensure seamless interoperability thanks to standardised, open communication protocols (KNX, Modbus RTU, BACnet MS/TP, BACnet/IP). Siemens controllers can be used in any system, including systems from other manufacturers.
We have VAV and communication – but why Siemens?
The main advantages of Siemens VAV controllers are:
- Easy mounting and low installation costs – fast, robust mounting with single-screw shaft fixing and a choice of form-fit inserts.
- Higher productivity thanks to easy programming – the AST20 handheld operating unit with a copy/paste function, intuitive menus and a backlit display makes programming and servicing simple.
- Tailored to customer needs – logo, cable type and length (PVC or halogen-free) and plug system on customer request.
- Instructions and documentation always at hand – the wiring diagram and a Data Matrix code (DMC) are printed on the devices and give direct access to key information.
- Position-independent measurement and high accuracy – measured values are acquired independently of the mounting position. High measuring accuracy even at low pressures (below 4 Pa). Temperature-compensated and stable over the long term without recalibration.
What is the best way to control a VAV installation?
A VAV installation properly managed by a higher-level system can reduce the energy consumption of air handling units by as much as 50%. The key lies in control algorithms that adjust the air handling units to the demand signalled by the rooms. If the indoor air quality is good, the energy-efficient approach is to reduce the airflow of the air handling unit rather than to throttle the VAV units.
Implementing this kind of control algorithm naturally requires extensive experience and appropriate, proven applications. However, the result achieved by combining the demand signals from the rooms with the control of the air handling units is well worth the effort. As a leading manufacturer of building automation systems, Siemens offers ready-made applications that ensure the highest energy efficiency of the ventilation system in a building.
I am constructing a modern building – what else can VAV offer?
The next step in optimising costs and the operation of room automation systems is to combine the functions of a VAV controller with those of an advanced room automation controller. In addition to air quality, such a hybrid controller can control lighting, blinds, radiators, air conditioning units and other systems. This integrated approach makes it possible to achieve the highest level of building energy efficiency while providing the right level of thermal comfort and air quality, together with adequate lighting and sun protection in occupied rooms.
Siemens VAV portfolio
Siemens VAV controllers – common specifications:
- Measuring range: 0–500 Pa
- Running time: 150 s
- Conformity: CE, RCM, UL, EAC
Compact and modular VAV controllers with 0/2...10 V control
| Type | Torque / damper area | Control signal | Operating voltage | Round shaft diameter (mm) | Square shaft size (mm) |
|---|---|---|---|---|---|
| GDB181.1E/3 | 5 Nm / approx. 0.8 m2 | 3-pos. / DC 0/2...10 V | AC 24 V | 8...16 | 6...12.8 |
| GLB181.1E/3 | 10 Nm / approx. 1.5 m2 | 3-pos. / DC 0/2...10 V | AC 24 V | 8...16 | 6...12.8 |
| ASV181.1E/3 | – | 3-pos. / DC 0/2...10 V | AC 24 V | – | – |
Compact VAV controllers with bus communication
| Type | Torque / damper area | Communication | Operating voltage | Round shaft diameter (mm) | Square shaft size (mm) |
|---|---|---|---|---|---|
| GDB181.1E/KN | 5 Nm / approx. 0.8 m2 | KNX / PL-Link | AC 24 V | 8...16 | 6...12.8 |
| GLB181.1E/KN | 10 Nm / approx. 1.5 m2 | KNX / PL-Link | AC 24 V | 8...16 | 6...12.8 |
| GDB181.1E/MO | 5 Nm / approx. 0.8 m2 | Modbus RTU | AC 24 V | 8...16 | 6...12.8 |
| GLB181.1E/MO | 10 Nm / approx. 1.5 m2 | Modbus RTU | AC 24 V | 8...16 | 6...12.8 |
| GDB181.1E/BA | 5 Nm / approx. 0.8 m2 | BACnet MS/TP | AC 24 V | 8...16 | 6...12.8 |
| GLB181.1E/BA | 10 Nm / approx. 1.5 m2 | BACnet MS/TP | AC 24 V | 8...16 | 6...12.8 |
VAV controllers integrated with room automation
| Type | Torque / damper area | Communication | Operating voltage | Round shaft diameter (mm) | Square shaft size (mm) |
|---|---|---|---|---|---|
| DXR2.E10PL-102B | 5 Nm / approx. 0.8 m2 | BACnet/IP + KNX | AC 24 V | 8...16 | 6...12.8 |
| DXR1.E10PL-112 | 10 Nm / approx. 1.5 m2 | BACnet/IP + KNX | AC 24 V | 8...16 | 6...12.8 |
| DXR1.E09PDZ-112 | 5 Nm / approx. 0.8 m2 | BACnet/IP + Modbus | AC 24 V | 8...16 | 6...12.8 |
About Siemens
Siemens has more than 170 years of experience in a successful and constantly expanding business. Its domain has always been technology – continuously developed, refined and modernised. Technology that ultimately serves people and makes their lives more comfortable, safer and easier. By focusing its activities on electrification, automation and digitalisation, Siemens sets the direction for future development.